Carrier 48fc 15 ton.

6 TON High Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ...

Carrier 48fc 15 ton. Things To Know About Carrier 48fc 15 ton.

3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48FCEA04A2A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models ... Brand Carrier; Equipment Type Commercial Packaged Outdoor Unit; Fan Type Vane Axial; Gas Stages 1-Stage;Gas Heating/Electric Cooling Models (48FC) 1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3.6 2 15.0 74 x 47 x 41 67 110 150 607 Gas Heating / Electric Cooling Models – 48FC Electric Heat / Electric Cooling & Cooling Only Models – 50FC Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) IEER Dimensions (in) L x W x H Electrical Heat Nominal kW Range Approx. Unit Weight (lbs) 3 1 (14.0) 74 x 47 x 33 4.0 to 15.0 43720 to 60 Nominal Tons. 48A2 – CV/SAV, Vertical. 48A3 - VAV, Vertical. 48A4 – CV/SAV, Horizontal. 48A5 - VAV, Horizontal. Carrier A Series Rooftop products are pre-wired and charged with refrigerant and tested in both cooling and heating modes at the factory. All models feature an industrial grade cabinet with fully hinged access panels.48FC WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology - Low Heat. Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/1. MFR: Item: 48FCDA04A2A30A0A0. Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/3. MFR:

Specification. AHRI System Builder. Description. Product Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: …04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel ExchangerCarrier 48FC 6 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208/230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;

According to FEC filings, Donald Trump, the Republican nominee for president, raised $22 million last month. By clicking "TRY IT", I agree to receive newsletters and promotions fro...20 to 60 Nominal Tons. 48A2 – CV/SAV, Vertical. 48A3 - VAV, Vertical. 48A4 – CV/SAV, Horizontal. 48A5 - VAV, Horizontal. Carrier A Series Rooftop products are pre-wired and charged with refrigerant and tested in both cooling and heating modes at the factory. All models feature an industrial grade cabinet with fully hinged access panels.

According to the U.S. Energy Information Administration, as of March 2014, the cost of coal per short ton ranged from $12 to $65. The quality of the coal determines the pricing of ...6 to 23 Nominal Tons. 48LC WeatherExpert® rooftop units were designed by customers for customers. They are Carrier’s most efficient commercial packaged rooftop ever produced and have some of the industry’s highest IEER’s available. The multi stage cooling compressor logic allows for added comfort, energy savings and humidity control.Choosing among a broad range of air conditioner brands can be overwhelming. So we've narrowed it down to two brands, YORK® and Carrier, to help you decide. Expert Advice On Improvi...12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; BTU Input 250000;Carrier BIM Drawings. Autodesk® Revit® BIM(Building Information Modeling) Drawings. Select your product 19PV --> Water Cooled Centrifugal Liquid Chiller30HXCPhaseIII --> Water Cooled Liquid Chiller/Heat Pump30KAV/30KAVP --> Variable-speed screw chiller with Greenspeed intelligence30KAVIZE --> Air Cooled Chiller / Heat Pump …

1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. All 48FC units comply with ASHRAE 90.1-2016 Energy Standard. 4. 48FC units comply with US Energy Policy Act (2005).

Carrier gas heat/electric cooling packaged rooftop 3 to 15 nominal tons (101 pages) ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages)

Sizes 04-06 models use single-stage cool-ing capacity control. FEATURES. Standard Base Unit Cabinet. Puron (R-410A) HFC refrigerant • Access panels with easy grip handles. SEER of 14.0 • Innovative, easy starting, no-strip screw feature on unit. Meets or exceeds ASHRAE 90.1 energy efficiency levels access panels.Overview. Performance series heat pumps offer that perfect balance between budget limits you may have today and your desire for long-term energy savings. The 25SPA5 boasts cooling efficiencies of up to 15.2 SEER2. And, like other Carrier heat pumps, it's designed to be Hybrid Heat® system compatible to help you save on heating costs in winter too.48TC*D/E units for installation in the United States contain use of Carrier's Staged Air Volume (SAV™) 2-speed indoor fan control system. This complies with the U.S. Department of Energy (DOE) efficiency standard of 2018. ... Fig.15 (size 08-16) for base rail details. See Fig. 6 (size 07) for thru-the-base charts.SEERs up to 14.0, IEER of 15.0. Gas efficiencies up to 82%. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain.Carrier 48FC Installation Instructions (2 pages) Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory Manual is suitable for 4 more products: 48 GC 48 HC 48 LC 48 TC8.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM09A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 09 = 8.5 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability …S Two cooling stage models are available from 7.5 -- 15 ton. S SEER up to 13.0. S EER’s up to 11.1. S IEER’s up to 11.8. S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs. S Utility connections are the same because 3 -- 12.5 ton units fit on existing Carrier rooftop curbs. This saves time and

15 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. ... 48fc-16-01si; Specifications. Brand Carrier; Availability Available for ...04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel ExchangerCarrier has introduced Weather Series Rooftop Units with EcoBlueTM Technology. One of EcoBlue's many innovative features is the exclusive beltless direct-drive vane axial fan that replaces traditional belt drive fans with a simpler, more compact design for improved performance and efficiency while decreasing maintenance and installation costs.Check out our list of family-friendly international carriers so you pick the right airline for your family's next flight. We'll tell you who offers infant and children's meals, spe...48FC WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology - Low Heat. Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/1. MFR: Item: 48FCDA04A2A30A0A0. Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/3. MFR:Features. Options. Physical Data. Documents. Performance Features. ASHRAE 90.1 compliant. Up to 13.0 SEER, 11.8 IEER, and 11.1 EER. Gas efficiencies up to 82% …Carrier 48FC 6 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 460-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F …

6 TON High Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A2A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... Carrier 48FCFM16A3A6-0A0A0 15 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU DCNE, 10 TON STAGE HEAT ROOFTOP GAS/ELECTRIC PACKAGE UNIT, VOLTAGE:460, HERTZ:60, PHASE:3, REFRIGERANT:R-22, CFM:4000, AFUE:80%, EER:9, ... WeatherMaker® 48FC Single …

InvestorPlace - Stock Market News, Stock Advice & Trading Tips To bears obsessed with “trees-in-the-forest” details like the yield... InvestorPlace - Stock Market N... Page 41: Rtu Open Controller (Factory Option) Completing Return Air Smoke Sensor Installation RTU Open Controller (Factory Option) Unscrew the two screws holding the Return Air Smoke For details on operating 48FC**04-07 units equipped with the Detector assembly. See Fig. 53, Step 1. 48FC WeatherMaker® Single-Packaged Rooftop Units with EcoBlue™ Technology - Low Heat. Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/1. MFR: Item: 48FCDA04A2A30A0A0. Carrier 3 Ton, 13.4 SEER2 Package RTU Low Gas Heating/Electric Cooling, Direct Drive/EcoBlue ,208/3. MFR: View and Download Carrier 48FC Series controls, start-up, operation and troubleshooting online. Single Package Rooftop Units with SystemVu Controls Version 1.X and Puronr (R-410A) Refrigerant. 48FC Series air conditioner pdf manual download. Also for: 50gc series, 48fc 04, 48fc 05,... 8.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48FCEM09A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium ...48FC units are single-packaged electric cooling, gas heating unit that are pre-wired and pre-charged with Puron® (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. Sizes 04-06 models use single-stage cooling capacity control. Size 07 models use two-stage cooling capacity control. FEATURES. Fig. 1 — 48FC 04-07 Model Number Nomenclature MODEL NUMBER RATED INDOOR AIRFLOW (CFM) 48FC*A/B04 1050 48FC*A/B05 1500 48FC*A/B06 2000 48FC*M/N07 2400 Model Series - WeatherMaker® FC – 14.0 SEER Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 – Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 ...

GAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and …

Three carrier hvac units named finalists in consulting-specifying Carrier 48tced manuals Weathermaker® 48fc single-packaged rooftop units with ecoblue™ technology Manualslib manuals 48tc. Manual and Guide Full List. Home; ... Carrier 14 Seer Air Conditioner - 2 Ton 14 Seer Icp Carrier Grandaire. Check Details.

•Carrier exclusive Ultra Low NOx gas heat emissions burner box and heat exchanger design that provides 14 nanograms/joule (ng/j) operation. •Reliable fixed speed scroll compres-sor on 3-5 ton sizes •Upgraded unit control board with intuitive indoor fan adjustment •Reliable copper tube/aluminum fin condenser coil with 5/ 16-in. tubingPuron Refrigerant is Carrier’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does ... Ratios) of 15.0 to 16.0, 12.0 to 12.5 EER, and AFUE (Annual Fuel Utilization Efficiency) ratings as high as 81%. ... ton). Coupled with the improved dehumidification associated withSEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit; Innovative corrosive-resistant composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drainIf you’re searching for a furnace to complete your HVAC system, Carrier’s offerings should be a great fit. Here’s what to expect from Carrier furnace costs. Expert Advice On Improv...Carrier provides a full line of packaged rooftop equipment to meet demanding HVAC systems requirements, from small electric cooling units to large gas heat/electric cooling units like the WeatherExpert® series, which has the industry’s highest part-load performance IEER ratings in the 3-5 ton range. Carrier DOAS (Dedicated Outdoor Air Systems) are …This product has been superseded by. 48FCEA04A3A5-0A0A0 - 3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTUReplacement for. 48KCEA06A2A5-0A0A0 - 5.0T G/E RTU PURON 208/230-3 MED FAN; 48TJE006---5--GA - 5.0T G/E RTU 3PH STD HEAT W/ALT MTR; 48FCEA06A2A5-0A0A0 - 5 TON Medium Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTUThis Comfort system offers that perfect balance between budget limits you may have today and your desire for long-term energy savings. It wraps together the summer comfort of an air conditioner with winter warmth from a gas furnace with a durable stainless steel heat exchanger. It also comes with a louvered hail guard for enhanced coil protection.

24 2 800 / 600 23000 12.0 15.0 30 2-1/2 1000 / 750 29000 12.0 15.0 36 3 1200 / 900 35400 12.5 16.0 42 3-1/2 1400 / 1050 42000 12.5 16.0 48 4 1600 / 1200 47500 12.3 16.0 60 5 1750 / 1200 57000 12.3 16.0 LEGEND dB ---Sound Levels (decibels) db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP---Coefficient of PerformanceGAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and time periods set forth herein. 24 2 800 / 600 23000 12.0 15.0 30 2-1/2 1000 / 750 29000 12.0 15.0 36 3 1200 / 900 35400 12.5 16.0 42 3-1/2 1400 / 1050 42000 12.5 16.0 48 4 1600 / 1200 47500 12.3 16.0 60 5 1750 / 1200 57000 12.3 16.0 LEGEND dB ---Sound Levels (decibels) db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP---Coefficient of Performance 04 - 3 ton 09 - 8.5 ton 05 - 4 ton 11 - 10 ton (12.0 EER)* 06 - 5 ton 12 - 10 ton (11.5 EER)* 07 - 6 ton 14 - 12.5 ton 08 - 7.5 ton Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat L = Low NOx - Low Gas Heat M = Low NOx - Medium Gas Heat N = Low NOx - High Gas Heat S = Low Heat with Stainless Steel ExchangerInstagram:https://instagram. ihop near seattle airporthow did gypsy rose get married in jailcraigslist furniture sacramento californiainovio buyout rumors 2022 8.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48FCEM09A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium ... palmetto state armory micro dagger release dategangs in san marcos ca cable-ready for connection to the Carrier Comfort Network (CCN), Carrier i--Vu , and Third Party BACnet* building management systems. The control provides high-speed communications for remote monitoring via the Internet. Multiple units can be linked together (and to other Direct Digital Control (DDC) equipped units) using a 3-wire communication ...Gas Heating/Electric Cooling Models (48FC) 1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3. h1b dropbox appointments india Carrier’s WeatherMaker® 15 to 27.5 ton rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, we’ve made your unit reliable and easy to install, maintain, and use. Easy to install These WeatherMaker units are designed for dedicated factory-sup- With so many cell phone carriers to choose from, it can be difficult to determine which one is the best fit for you. The first step in finding the right cell phone carrier is to ev...Carrier 48fc 15 Ton, Carrier Commercial Packaged Outdoor Commercial Products Portland, OR, Commercial Cooling Showcase 2019 2019-05-06 ACHR News